Fire Prevention
Division
Isolcell ORS (Oxygen Reduction Systems) prevent fires before they develop by creating an environment in which combustion is impossible. This proactive approach ensures safety, overcoming the limitations of traditional fire protection systems.
Fire Prevention
Division
Isolcell ORS (Oxygen Reduction Systems) prevent fires before they develop by creating an environment in which combustion is impossible. This proactive approach ensures safety, overcoming the limitations of traditional fire protection systems.
We provide technologies to create oxygen-reduced atmospheres for fire prevention.
Prevention: the smarter way to protect.
Conventional fire protection systems are reactive: they act only after a fire has started and damage may already have occurred. Water-based systems such as sprinklers or foam systems, as well as gas extinguishing systems, can also introduce additional risks to buildings, equipment, business continuity and people’s safety.
N2 ORS® removes the fear of fire by creating an environment that prevents a fire from developing in the first place.
With over 65 years of experience in controlled atmospheres, Isolcell has been a pioneer in fire prevention for more than 20 years with its advanced OR systems. This leadership is confirmed by the certifications obtained for our N2 ORS® system, including ÖNORM, EN 16750, ISO 20338, IEC 61508 and VdS.
The elements required for
combustion
Oxygen 21%
Fuel
Heat
Oxygen 19%
Fuel
Heat
Oxygen 17%
Fuel
Heat
Gas concentrations
N2 Oxygen Reduction System
Gas concentrations
normal air
The fire
triangle
The air we breathe consists mainly of nitrogen and oxygen. Nitrogen is inert, while oxygen supports combustion. A fire can develop only when three elements are present simultaneously: combustible material, oxygen and an ignition source. These three elements form the fire triangle. Removing even one prevents combustion from starting or continuing. By lowering oxygen below the level needed for combustion, a controlled atmosphere prevents fires from developing.
Fire prevention through oxygen reduction is based on maintaining a lower-than-normal oxygen concentration in the protected area. This is achieved by adjusting the balance between oxygen and nitrogen, creating an atmosphere richer in nitrogen and lower in oxygen. The result is a fire-preventive atmosphere that inhibits combustion while remaining natural and tolerable for the human body.
OR systems provide safe environments for people without compromising access to the building.
Benefits of the
oxygen depletion method
Ignition prevention
Eliminates the risk of fire
Zero false alarms
Constant protection (24/7/365)
Complete protection
No damage from extinguishing agents
No residue
Adjustable oxygen concentration (depending on the material
to be protected)
Continuous protection
Business continuity
No unintended activation
No manual activation required
Environmental sustainability
Natural
Environmentally friendly
Tolerable for humans
Additional benefits of the N2 ORS® system
Precision
Virtual Grid accuracy
Greater adaptability to the area being protected
Safety
System compliant with standards and certified
System redundancy
Greater safety in oxygen measurement
Equipped with self-diagnostic tools
Simplicity
Plug & play installation
Easy to reprogram
Remote system monitoring
Versatility
Adaptable even in areas subject to regulatory constraints
Suitable for any risk class
Can be integrated with existing systems
Flexibility
Extensive customisation
Minimal intrusion into the protected area
Quiet operation
Cost efficiency
Lower operating and maintenance costs
Reduced energy consumption
Operating principle
N2 ORS®
in four simple steps
The N2 ORS® system creates and maintains an oxygen-reduced atmosphere using electrically powered equipment based on molecular separation technology. Thanks to the Virtual Grid and the modular design of the generators, the system optimises energy consumption and operating costs. The units operate in rotation, reducing operating hours, limiting wear and minimising maintenance requirements.
1 / Generate
The system generates an oxygen-reduced atmosphere using only ambient air, without chemicals or additives.
2 / Supply
The generated atmosphere is supplied to the protected area through a dedicated distribution network.
3 / Monitor
A Virtual Grid of oxygen sensors continuously monitors the atmosphere throughout the protected area and sends real-time data to the control panel.
4 / Maintain
If the oxygen level moves outside the defined range, the control panel automatically activates the generators for the time required to restore the set values.
Products
Oxygen-Reduced
Air Generators
With experience dating back to 1958, Isolcell provides all the key technologies for generating oxygen-reduced atmospheres.
To meet different application requirements, Isolcell offers nitrogen generators based on all the main molecular air separation technologies.
Isosep series
membrane technology
Nimos series
PSA technology (Pressure Swing Adsorption)
ADOX® series
VPSA technology (Vacuum Pressure Swing Adsorption)
Technology
Made by Isolcell
With over 65 years of experience in generated and controlled atmosphere technologies, ISOLCELL offers advanced, customised oxygen reduction systems that combine innovation, flexibility and certified safety.
From design to production
Quality and reliability guide every stage of our process, from design to production. In safety systems, this is the foundation for lasting performance and customer trust.
Oxygen-reduced atmospheres and people
Air consists mainly of nitrogen and oxygen: approximately 78.08% nitrogen and 20.95% oxygen by volume, with small amounts of argon and CO₂. This balance is essentially the same worldwide, from sea level to high altitudes. Within defined limits, reduced oxygen levels can be tolerated by people in good health. The effects are comparable to those experienced at higher altitudes.
Benefits of the system
N2 ORS®
Fire prevention technology
Proactively prevents fires by modifying the composition of the atmosphere.
Science-based safety
Safely reduces oxygen levels without compromising human health.
Effective fire risk management
A proven solution for protecting critical areas and facilities.
Global applicability
Works effectively in any environment, from low-lying areas to high-altitude locations.
N2 Oxygen Reduction System® sets a new standard in fire prevention technology, offering a reliable, innovative solution for protecting people and property.
Information on access
to protected areas
Access guidelines
are provided by
AI, Labour Inspectorate (Arbeitsinspektorat).
SUVA, Swiss National Accident Insurance Fund.
DGUV, German Social Accident Insurance.
UIAA, Medical Commission of the International Climbing and Mountaineering Federation.